Showing 793–816 of 1211 results

Show sidebar

Oxacillin 256 M.I.C.E. (50 Pack)

Brand:

Thermo ScientificTM OxoidTM

**This product is not available at the moment.

Effortlessly establish accurate Minimum Inhibitory Concentration (MIC) values manually using Thermo Scientific™ Oxoid™ Oxacillin M.I.C.Evaluator Strips (M.I.C.E.™).

Oxacillin Resistance Screening Agar 500g

Brand:

Thermo ScientificTM OxoidTM

This product has been discontinued. Please contact us for more information.

  • Oxoid Oxacillin Resistance Screening Agar Base (ORSAB) is a medium for screening clinical samples for the presence of oxacillin-resistant Staphylococci.
  • Also available ORSAB Selective Supplement, Part No. SR0195E.

Oxacillin Resistance Screening Agar Base (ORSAB), Oxoid Composition

Typical Formula*

gm/litre

Peptone

11.8

Yeast Extract

9.0

Mannitol

10.0

Sodium chloride

55.0

Lithium chloride

5.0

Aniline Blue

0.2

Agar

12.5

PH 7.2 ± 0.2 @ 25°C

 

Oxacillin Resistance Screening Agar, Oxoid Preparation:
Suspend 51.75g of Oxacillin Resistance Screening Agar Base in 500ml of distilled water and bring gently to the boil to dissolve. Sterilise by autoclaving at 121°C for 15 minutes. Cool to 50°C and aseptically add the contents of one vial of ORSAB Selective Supplement SR0195, reconstituted as directed below. Mix well and pour into sterile Petri dishes.

Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C.

Oxoid Anaerogen 2.5L (10 Pack)

Brand:

Thermo ScientificTM OxoidTM

Thermo Scientific™ Oxoid AnaeroGen 2.5L Sachets are anaerobic gas generating sachets. It can be used to generate an anaerobic system when using with Thermo Scientific™ Oxoid 2.5L jar, Part No. AG0025A. The anaerobic condition can be determined using Anaerobic Indicator. Once the anaerobic condition is generated, it is suitable to grow anaerobes, which favour carbon dioxide.

Features of Oxoid AnaeroGen

  • No water or catalyst required
  • No hydrogen gas produced

Oxoid M.U.G. Supplement 1 X 10 Vials

Brand:

Thermo ScientificTM OxoidTM

Oxoid MUG Supplement (50mg) Fluorescent agent is used for the detection of E. coli.

  • Contains 4-methylumbelliferyl-β-D-glucuronide (MUG)
  • Each vial supplements 500mL of medium

M.U.G. Supplement, Oxoid Composition

Vial content
4-methylumbelliferyl-ß-D-glucuronide50mg

 

M.U.G. Supplement, Oxoid Preparation:

Add 2ml of distilled water to a vial and invert gently until completely dissolved. Add the vial contents to the following volumes of suggested media, before sterilisation.

Medium

Final conc. of MUG per litre

Number of vials per litre

Violet Red Bile Agar CM0107

100mg

2

MacConkey Agar No. 3 CM0115

100mg

2

Brilliant Green Bile (2%) Broth CM0031

50mg

1

MacConkey Broth Purple CM0505

50mg

1

Lauryl Tryptose Broth CM0451

50mg

1

 

Storage conditions and Shelf life
Should be stored at 2-8°C. When stored as directed the unopened vial is stable until the expiry date on the label.

Precautions
The presence of endogenous glucuronidase in shellfish samples may result in false positive fluorescence. Test tubes used in the MPN method should be checked under UV light to ensure the glass does not fluoresce. To avoid false positive fluorescence the source of long wave UV light must not exceed 6 watts.

Oxoid Resazurin Anaerobic Indicator

Brand:

Thermo ScientificTM OxoidTM

Oxoid Resazurin anaerobic indicator is an indicator strip for use with anaerobic jar systems, AnaeroJar 2.5L and AnaeroGen, 2.5L. When this anaerobic indicator strip changes from red to white, you can ensure the anaerobic condition is well generated.

Oxytetracyclin Glucose Yeast Extract 500g

Brand:

Thermo ScientificTM OxoidTM

Selectively enumerate yeasts and molds from foodstuffs with Thermo Scientific™ Oxoid™ Oxytetracycline Glucose Yeast Extract Agar Base (Dehydrated). The medium is based upon the formulation described by Mossel et al. which utilizes oxytetracycline selectivity to provide increased counts of yeasts and molds compared to other media that utilize a low pH as a selective agent. Improve the recovery of physically stressed yeast cells on this neutral pH medium.

Oxytetracycline Glucose Yeast Extract Agar Base (Dehydrated), Oxoid Composition

Typical Formula*

gm/litre

Yeast extract

5.0

Glucose

20.0

Agar

12.0

pH 7.6 ± 0.2 @ 25°C

 

Oxytetracycline Glucose Yeast Extract Agar, Oxoid Preparation:
Suspend 18.5g in 500ml of distilled water and bring gently to the boil to dissolve completely. Sterilise by autoclaving at 115°C for 10 minutes. Allow the medium to cool to 50°C and aseptically add the contents of one vial of Oxytetracycline GYE Selective Supplement (SR0073) reconstituted as directed. Mix thoroughly and pour into sterile Petri dishes. The pH of this medium should be 7.0±0.2 @ 25°C.

Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C.

Precautions:
The lactic-acid bacteria are inhibited on this medium.

P1 Penicillin G

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Penicillin G Antimicrobial Susceptibility Disks.

P1.5 Penicillin G

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Penicillin G Antimicrobial Susceptibility Disks.

P10 Penicillin G

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Penicillin G Antimicrobial Susceptibility Disks.

P2 Penicillin G

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Penicillin G Antimicrobial Susceptibility Disks.

P5 Penicillin G

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Penicillin G Antimicrobial Susceptibility Disks.

Pair Notch20 x 20cm Glass Plate

Brand:

Cleaver Scientific

Pair Notch20 x 20cm glass plate with 6mm wide spaces to run IEF strips.

Palcam Agar Base 500g

Brand:

Thermo ScientificTM OxoidTM

  • Oxoid PALCAM Agar Base is a selective and diagnostic medium for the detection of Listeria monocytogenes.
  • Also available PALCAM Selective Supplement, Part No. SR0150E or SR0150B.

PALCAM Agar Base, Oxoid Composition

Typical Formula*

gm/litre

Columbia Blood Agar Base

39.0

Yeast extract

3.0

Glucose

0.5

Aesculin

0.8

Ferric ammonium citrate

0.5

Mannitol

10.0

Phenol red

0.08

Lithium chloride

15.0

pH 7.2 ± 0.2 @ 25°C

 

PALCAM Agar, Oxoid Preparation:
Suspend 34.5g per 500ml of distilled water. Bring gently to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes. Cool to 50°C, and aseptically add PALCAM Selective Supplement (SR0150), reconstitutes as directed. Mix well and pour into sterile Petri dishes.

The addition of 2.5% (v/v) Egg Yolk Emulsion (SR0047) to the medium may aid the recovery of damaged Listeria.

Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
The prepared medium may be stored for up to 4 weeks at 2-8°C in the dark.

Precautions
Acriflavine hydrochloride is activated by light which may cause it to become inhibitory to Listeria growth.

PALCAM Supplement 1 X 10 Vials

Brand:

Thermo ScientificTM OxoidTM

Thermo Scientific™ Oxoid PALCAM Supplement is a selective supplement for use with PALCAM Agar Base.

PALCAM Supplement, Oxoid Composition

Typical Formula*
per litre
Polymyxin B

10.0mg

Acriflavine hydrochloride

5.0mg

Ceftazidime

20.0mg

 

PALCAM Agar, Oxoid Preparation:
Suspend 34.5g per 500ml of distilled water. Bring gently to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes. Cool to 50°C, and aseptically add PALCAM Selective Supplement (SR0150), reconstitutes as directed. Mix well and pour into sterile Petri dishes.

The addition of 2.5% (v/v) Egg Yolk Emulsion (SR0047) to the medium may aid the recovery of damaged Listeria.

Storage conditions and Shelf life
Store the selective supplement in the dark at 2-8°C and use before the expiry date on the label.
The prepared medium may be stored for up to 4 weeks at 2-8°C in the dark.

Palm Micro Centrifuge

Brand:

Biologix

This item is not available at the moment. Please contact us for more information.

The Palm Micro Centrifuge is a very small, compact centrifuge ideal for microfiltration and quick spins. It has been tested and approved in accordance with IEC/EN61010-2-20.

Features
• Fixed speed: 7000 rpm
• Quick acceleration and deceleration
• Rotors for microcentrifuge tubes, PCR tubes, and PCR 8-strip tubes included
• Easily change rotors without tools
• Quiet, low-noise design

Palm Micro Centrifuge Brochure

Parafilm M® All-Purpose Laboratory Film

Brand:

VWR

Parafilm, a semi-transparent, flexible film that adheres quickly and firmly. It can be sealed to itself, culture tubes or flasks and petri dish edges.

  • Waterproof sheet interwound with paper to prevent adhering
  • Flexible, odourless and tasteless
  • Resistant to air, gases, alcohol, acids and alkalies
Stretches 200% at 21 °C and returns partially to its original size. At 82 – 93 °C, it softens enough to make an adhesive bond between papers, cloths, leathers, etc.

Paternity Testing – Electrophoresis Education kit

Brand:

Cleaver Scientific

In this experiment, DNA from a mother, child and 2 possible fathers is seperated by electrophoresis to determine the paternity of the child. The human DNA is simulated with a series of unqiue fragments that form a profile for each sample, allowing students to identify the father based on the mother and childs seperation profiles.

This kit includes DNA, Agarose, electrophoresis buffer and DNA stain for 8 student groups.

Key Features

  • Perfect for 1 hour lessons
  • Introduce students to DNA and genetics
  • Works perfectly with Cleaver Scientific equipment

Pb300 Polymyxin B

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Polymyxin B Antimicrobial Susceptibility Disks.

PCR Marker

Brand:

New England Biolabs

  • Size range: 50 bp to 766 bp
  • Value pricing
  • Supplied with free vial of Gel Loading Dye, Purple (6X), no SDS (NEB #B7025).
  • Easy to identify reference bands
  • Small size suitable for 100 gel lanes; large size suitable for 500 gel lanes

PCR Single Tubes, Biologix

Brand:

Biologix

This item is not available at the moment. Please contact us for more information.

Characteristics
● Made of prime virgin polypropylene
● Ultra thin-wall offers high degree of transparency, easy for observation and heat conduction
● Domed caps ensure efficient heat transfer, while flat caps are ideal for Real-Time PCR(qPCR), Unique design prevents opening during cycling and incubation
● DNase, RNase, and endotoxin free
● Temperature range: stable from -20ºC to 100ºC
● Universal fits for the PCR instrument; Withstand centrifugation of 6,000 RCF in a fully supported rotor
* Assorted colors for PCR tubes should be ordered separately

PCR Single Tubes, Biologix (1000/Pack)

Brand:

Biologix

This product is currently not available. Please contact us for more information.

Characteristics
● Made of prime virgin polypropylene
● Ultra thin-wall offers high degree of transparency, easy for observation and heat conduction
● Domed caps ensure efficient heat transfer, while flat caps are ideal for Real-Time PCR(qPCR), Unique design prevents opening during cycling and incubation
● DNase, RNase, and endotoxin free
● Temperature range: stable from -20ºC to 100ºC
● Universal fits for the PCR instrument; Withstand centrifugation of 6,000 RCF in a fully supported rotor
* Assorted colors for PCR tubes should be ordered separately

Pef5 Pefloxacin

Brand:

Thermo ScientificTM OxoidTM

Manually determine the antibiotic susceptibility of microorganisms using Antimicrobial Susceptibility Testing (AST) methods in conjunction with reliable, easy-to-use Thermo Scientific™ Oxoid™ Pefloxacin Antimicrobial Susceptibility Disks.

Pefringens Agar 500g

Brand:

Thermo ScientificTM OxoidTM

  • Oxoid Perfringens OPSP Agar Base is used for the enumeration of Clostridium perfringens in foods.
  • lso available Perfringens OPSP Supplement A, Part No. SR0076E and Perfringens OPSP Supplement B, Part No. SR0077E.

Perfringens OPSP Agar Base, Oxoid Composition

Typical Formula*

gm/litre

Tryptone

15.0

Yeast extract

5.0

Soya peptone

5.0

Liver extract

7.0

Ferric ammonium citrate

1.0

Sodium metabisulphite

1.0

Tris buffer

1.5

Agar

10.0

pH 7.3 ± 0.2 @ 25°C

 

Perfringens OPSP Agar, Oxoid Preparation:
Suspend 22.8g in 500ml of distilled water and bring gently to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes. Allow to cool to 50°C and aseptically add the contents of one vial each of Perfringens Agar (OPSP) supplements A and B (SR0076 and SR0077) which have been rehydrated as directed. Mix well and pour into sterile dishes.

Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C.

Precautions
The production of black colonies on this medium is a presumptive identification of Clostridium perfringens. Further identification tests must be carried out.

Penase 1 Vial

Brand:

Thermo ScientificTM OxoidTM

A Bacillus cereus 569/H9 lactamase (E.C.5.2.6) presented as a freeze-dried powder containing buffer salts. Each vial contains a 3,300lU of activity (1 unit of enzyme activity will hydrolyse 1.0μmol of benzylpenicilloic acid per minute pH7.0 and at 25°C).

Used for the inactivation of susceptible beta-lacram antibiotics in preparations, blood or tissue samples.