Clindamycin 256 M.I.C.E. (10 pack)
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
**This product is not available at the moment.
Effortlessly establish accurate Minimum Inhibitory Concentration (MIC) values manually using Thermo Scientific™ Oxoid™ Clindamycin M.I.C.Evaluator Strips (M.I.C.E.™).
Clindamycin 256 M.I.C.E. (50 pack)
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
**This product is not available at the moment.
Effortlessly establish accurate Minimum Inhibitory Concentration (MIC) values manually using Thermo Scientific™ Oxoid™ Clindamycin M.I.C.Evaluator Strips (M.I.C.E.™).
Clostridium Difficile Selective Supplement 1 x 10 Vials
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
- Oxoid Clostridium Difficile Selective Supplement is added to Clostridium Difficile Agar Base, Part No. CM0601B.
- Each vial supplements 500mL of medium.
Clostridium Difficile Selective Supplement, Oxoid Composition
Vial contents (each vial is sufficient for 500mls of medium) |
per vial
|
per litre
|
D-cycloserine |
125.0mg
|
250.0mg |
Cefoxitin |
4.0mg
|
8.0mg |
Clostridium Difficile Agar, Oxoid Preparation:
Suspend 34.5g in 500ml of distilled water and bring gently to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes. Allow to cool to 50°C and add aseptically the contents of 1 vial of Oxoid Clostridium Difficile Supplement (SR0096) reconstituted as directed, together with 7% (v/v) Defibrinated Horse Blood (SR0050). Sheep Blood (SR0051) may be used in place of Horse Blood but some strains of the organism will show a slightly reduced growth recovery. Mix well and pour into sterile Petri dishes.
Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C no longer than 5-7 days.
Clostridiunm Difficile 500g
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
- Oxoid Clostridium Difficile Agar Base is used for the isolation of Clostridium difficile.
- Also available Clostridium Difficile Selective Supplement, Part No. SR0096E.
lostridium Difficile Agar Base, Oxoid Composition
Typical Formula* |
gm/litre |
Proteose peptone |
40.0 |
Disodium hydrogen phosphate |
5.0 |
Potassium dihydrogen phosphate |
1.0 |
Magnesium sulphate |
0.1 |
Sodium chloride |
2.0 |
Fructose |
6.0 |
Agar |
15.0 |
pH 7.4 ± 0.2 @ 25°C |
Clostridium Difficile Agar, Oxoid Preparation:
Suspend 34.5g in 500ml of distilled water and bring gently to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes. Allow to cool to 50°C and add aseptically the contents of 1 vial of Oxoid Clostridium Difficile Supplement (SR0096) reconstituted as directed, together with 7% (v/v) Defibrinated Horse Blood (SR0050). Sheep Blood (SR0051) may be used in place of Horse Blood but some strains of the organism will show a slightly reduced growth recovery. Mix well and pour into sterile Petri dishes.
Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C no longer than 5-7 days.
Precautions
Colonies of Clostridium difficile from faecal cultures are smaller when egg yolk is used in place of horse blood.
The Oxoid formula does not contain the neutral red indicator proposed by George et al. because it is designed for use with horse blood. On this medium the typical colour of the colony of Clostridium difficile will not appear however there will be a fluorescent reaction.
Typical Gram stain morphology of Clostridium difficile may not be evident in colonies picked from this medium because of the antibiotics present. Subculture to blood agar to obtain characteristic morphology.
Clr15 Clarithromycin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Clr5 Clarithromycin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Cn10 Gentamicin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Cn120 Gentamicin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Cn200 Gentamicin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Cn30 Gentamicin
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Co2gen 10/Pck
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Generate carbon dioxide atmosphere in AnaeroJar™ 2.5L with Oxoid CO2 Gen Sachet.
- No water or catalyst required
- No hydrogen gas produced
Co2gen Compact 20/Pck
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Oxoid CO2 Gen Compact Sachet is for use in Compact Plastic Pouch.
- No water or catalyst required
- No hydrogen gas produced
- For use with Compact Plastic Pouch, Part No. AG0020C and AnaeroGen Compact Sealing Clip, Part No. AN0005C
Cobalt (II) nitrate hexahydrate CP, 500g
Login to see pricesBrand:
Chemiz
Description
Synonyms: Cobaltous nitrate hexahydrate
Formula: Co(NO3)2 · 6H2O
Cobalt (II) nitrate hexahydrate is a red crystal that is soluble in water and most organic solvent. This chemical has many use including cleaning, metal manufacturing and metal surface treatment.
Note:
AR: Analitycal Reagent Grade: Reagents for analytical purpose or research work that need high purity.
CP: Chemically Pure Grade: Reagents for regular practical in its original purity.
Color Prestained Protein Standard, Broad Range (10-250 kDa)
Login to see pricesBrand:
New England Biolabs
The Color Prestained Protein Standard, Broad Range is a mixture of highly pure, recombinant, prestained proteins, covalently coupled with a blue chromophore, and two reference bands (one orange and one green at 72 kDa and 26 kDa, respectively), that resolves into 11 sharp bands when electrophoresed.
- Allows approximate molecular weight determination when performing SDS-PAGE analysis
- Applications include verification of Western transfer efficiency on membranes and fluorescent imaging of SDS-PAGE
- Direct loading, additional loading buffer and heat incubation not required
- Recombinant proteins with no detectable protease contaminating activities
- Optimal stability for up to 24 months
Columbia Blood Agar Base 500g
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Cultivate and isolate fastidious microorganisms with clearly visible hemolytic reactions with Thermo Scientific™ Oxoid™ Columbia Blood Agar Base (Dehydrated) when used with whole defibrinated blood (SR0050). Columbia Blood Agar Base is an ideal base medium for preparation of blood agar, chocolate agar and for preparation of various selective and identification media.
Columbia Blood Agar Base, Oxoid Composition
Typical Formula* |
gm/litre |
Special peptone |
23.0 |
Starch |
1.0 |
Sodium chloride |
5.0 |
Agar |
10.0 |
pH 7.3 ± 0.2 @ 25°C |
Columbia Blood Agar, Oxoid Preparation:
Add 39g to 1 litre of distilled water. Boil to dissolve the medium completely. Sterilise by autoclaving at 121°C for 15 minutes. Cool to 50°C and add 5% sterile defibrinated blood.
Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared plates of medium at 2-8°C.
Precautions
Brucella cultures are highly infective and must be handled under properly protected conditions. Incubate in 5-10% carbon dioxide atmosphere for 24-48 hours.
Campylobacter species are best grown at 42°C (except Campylobacter fetus subsp. fetus) in a micro-aerophilic atmosphere (Oxoid Campylobacter Gas Generating Kit BR0056 or BR0060 or CampyGen CN0025/CN0035).
Staph./Strep. supplemented plates should be incubated aerobically at 35°C for 18 hours. Incubation in carbon dioxide- enriched air will cause inhibition of staphylococcal growth.
Streptococcus Selective Supplement SR0126 supplemented plates may be incubated aerobically or anaerobically at 35°C for 18 hours.
Prepared plates of both supplemented media should be used within 18 hours of preparation for maximum selectivity. Gardnerella supplemented plates should be incubated at 35°C for 48 hours in an atmosphere containing 7% carbon dioxide.
Carry out confirmatory tests on all colonies from horse blood medium and on beta-haemolytic colonies from human or rabbit blood medium.
Incubate plates of Clostridium E-Y Agar anaerobically at 35°C for 18 hours, look for lecithinase activity (pearly layer) and for proteolysis. Lecithinase activity is inhibited in the presence of specific anti-toxin.
CombiTitrant 5 , 1L (Merck)
Login to see pricesBrand:
Merck
Description
CAS Number : 7553-56-2
Density : 1.19 g/cm3 (20 °C)
One-component reagent for volumetric Karl Fischer titration 1 ml ≙ ca. 5 mg H₂O Aquastar®
Complete 2-D Systems – Mini to Maxi
Login to see pricesBrand:
Cleaver Scientific
The omniPAGE 2-D Systems include both modules required for Slab Gel and First Dimension Electrophoresis and accessories, to provide a complete Mini, Mini Wide or Maxi 2-D system. The Tube Gel Module includes a rapid release gasket for easy tube extraction. Focusing can be accomplished in as little as three hours in the Mini Unit. Disposable capillary tubes are included for added convenience, plus 2-D combs and spacers which are colour coded according to thickness for easy identification.
Package includes:
- 1x omniPAGE Mini Vertical Unit which includes: 2x2mm thick notched glass plates, 2x2mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick 12 samples), 1x casting base, silicone mat, cooling pack
- 1x Capillary electrophoresis module which includes: internal running module for tube gels, capillary tubes, blanking plugs, 2-D combs and spacers
Complete Denaturing Gradient Electrophoresis System
Login to see pricesBrand:
Cleaver Scientific
Denaturing Gradient Gel Electrophoresis (DGGE) is an important technique used in the search for mutations and DNA polymorphisms critical in genetic disorders and cancers, and to understand genetic diversity among species. The new omniPAGE VS20WAVE-DGGE is a flexible system that can be fully customised to perform several different mutation detection techniques. The VS20WAVE-DGGE is a versatile single-unit solution for different single-base pair mutation detection methods. The newly designed VS20WAVE-DGGE is a complete system for DNA mutation analysis.
Complete Mini Wide Vertical Electrophoresis Modular System
Login to see pricesBrand:
Cleaver Scientific
The omniPAGE range of Modular Vertical Gel Systems allow multiple electrophoresis techniques to be performed in the same unit. These systems include all modules and accessories required for Slab Gel Electrophoresis, 2-D Electrophoresis and Electroblotting. The central component is the omniPAGE Mini Vertical unit, Mini Wide Vertical Unit or omniPAGE Maxi Vertical unit.
Package includes:
- 1x omniPAGE Mini Wide Vertical Unit which includes: 2x4mm thick notched glass plates, 2x4mm thick plain glass plates with 1mm thick bonded spacers, 1x dummy plate, 2x combs (1mm thick, 24 samples), 1x casting base, silicone mat, cooling pack
- 1x Capillary Electrophoresis Module which includes: internal running module for tube gels, capillary tubes, blanking plugs, 2-D combs and spacers
- 1x Electroblotting Module comprising: internal electroblotting module, 4x compression cassettes for gel sizes up to 20x10cm and 6x fibre pads.
Complete System for Mini Vertical Electrophoresis
Login to see pricesBrand:
Cleaver Scientific
The omniPAGE range of Modular Vertical Gel Systems allow multiple electrophoresis techniques to be performed in the same unit. These systems include all modules and accessories required for Slab Gel Electrophoresis, 2-D Electrophoresis and Electroblotting. The central component is the omniPAGE Mini Vertical unit, Mini Wide Vertical Unit or omniPAGE Maxi Vertical unit. These include a rapid and intuitive casting system, enhanced and easy to set up cooling system and increased capacity to run up to four gels per run.
Complete WAVE Maxi System for 2-D Electrophoresis & Blotting
Login to see pricesBrand:
Cleaver Scientific
The VS20 WAVE complete electrophoresis system provides a fully integrated solution using one universal gel tank and lid for vertical PAGE, tube gel IEF and electroblotting:
- Interchangeable modular inserts allow users to combine vertical PAGE with capillary gel IEF to perform 2-D electrophoresis, followed by western transfer for enhanced sensitivity
- Scale-up your discovery projects using a large format, high-resolution system
- Cooling supplied for temperature-sensitive separations and samples
- High-intensity blotting system available for rapid transfers
Complete WAVE Maxi System for 2-D Electrophoresis & High Intensity Blotting
Login to see pricesBrand:
Cleaver Scientific
The VS20 WAVE complete electrophoresis system provides a fully integrated solution using one universal gel tank and lid for vertical PAGE, tube gel IEF and electroblotting.
- Interchangeable modular inserts allow users to combine vertical PAGE with capillary gel IEF to perform 2-D electrophoresis, followed by western transfer for enhanced sensitivity
- Scale-up your discovery projects using a large format, high-resolution system
- Cooling supplied for temperature-sensitive separations and samples
- High-intensity blotting system available for rapid transfers
Cooked Meat Medium 500g
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Grow and maintain aerobic and anaerobic organisms with Thermo Scientific™ Oxoid™ Cooked Meat Medium (Dehydrated). The medium contains heart tissue, beef extracts, peptone and glucose for the cultivation of anaerobic and aerobic organisms. It has the ability to initiate bacterial growth from very small inocula and to maintain the viability of cultures over long periods of time1. Mixed cultures of bacteria survive in Cooked Meat Medium without displacing the slower growing organisms.
Cooked Meat Medium, Oxoid Composition
Typical Formula* |
gm/litre |
Heart muscle |
454.0 |
Peptone |
10.0 |
`Lab-Lemco’ powder |
10.0 |
Sodium chloride |
5.0 |
Glucose |
2.0 |
pH 7.2 ± 0.2 @ 25°C |
Cooked Meat Medium, Oxoid Preparation:
Suspend 10g in 100ml of distilled water (or 1g amounts in 10ml volumes of water in tubes). Allow to stand for 15 minutes until the meat particles are thoroughly wetted. Sterilise by autoclaving at 121°C for 15 minutes. Do not cool the bottles rapidly because ebullition will expel the meat particles from the containers.
Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at room temperature, in the dark with tightened caps for up to 6 months.
Precautions
The excellent recovery properties of Cooked Meat Medium mean that mixed cultures commonly result from sample inoculation.
Blackening of the medium will not take place if the pH is acid.
Carbohydrate fermentation may inhibit proteolysis.
Corn Meal Agar 500g
Login to see pricesBrand:
Thermo ScientificTM OxoidTM
Oxoid Corn Meal Agar Mycological medium is used for identification of Candida albicans and maintenance of fungal stock cultures.
Corn Meal Agar, Oxoid Composition
Typical Formula* |
gm/litre |
Corn Meal Extract (from 50 grams whole maize) |
2.0 |
Agar |
15.0 |
pH 6.0 ± 0.2 @ 25°C |
|
Corn Meal Agar, Oxoid Preparation:
Suspend 17g in 1 litre of distilled water. Bring to the boil to dissolve completely. Sterilise by autoclaving at 121°C for 15 minutes.
Storage conditions and Shelf life
Store the dehydrated medium at 10-30°C and use before the expiry date on the label.
Store the prepared medium at 2-8°C.
Precautions
Glucose supplemented Corn Meal Agar should not be used for chlamydospore production.
Corn Meal Agar with `Tween 80’ (or other wetting agents) will allow Candida stellatoides and Candida tropicalis to produce chlamydospores.
Some Candida strains lose their ability to produce chlamydospores after repeated subculturing.